Home > Failed With > Failed With Abend Aei9

Failed With Abend Aei9

Bad Subscript / Index     2. An E37 on tape datasets is most often caused when the number of requested volumes is exceeded. If this post answer your question. AEIx and AEYx There are numerous abends that start with AEI or AEY. http://1pxcare.com/failed-with/failed-with-err-5-eio.html

Program has taken more CPU time than the default limit for        the JOB Class could indicate an infinite loop S522    -    JOB or TSO session exceeded maximum job wait Check for subscript errors, missing DD card, file not opened.     (Missing / Misspelled DD name, Read / Write to un-opened dataset, Read to dataset that opened in       OUTPUT mode, ATDD The destination that was specified in a transient data request is disabled. The maximum number of extents would be exceeded. http://www.ibm.com/support/knowledgecenter/SSGMCP_5.2.0/com.ibm.cics.ts.messages.doc/AExx_abend_codes/AEI9.html

THE PROGRAM SHOULD BE INVOKED UNDER THE DSN COMMAND   SQLCODE  -926, Error: ROLLBACK NOT VALID IN IMS OR CICS ENVIRONMENT   SQLCODE  -925, Error: COMMIT NOT VALID IN IMS OR May need a JOBLIB or STEPLIB.  S0C1 Executing a program with an unresolved external reference. o        Following a READ UPDATE command for a data set, a WRITE or READ UPDATE command is issued for the same data set before exclusive control is released. They indicate that an exception has occured, and RESP (or NOHANDLE) is not is use.

The ICVR parameter in the CICS SIT table can be used to specify a value for all tasks running in CICS, or you can specify a RUNAWAY value when a transaction o        The data area specified in the RIDFLD is not the same one in all the commands of a browse. Barring that, however, you program MUST be able to handle the condition. S0C1    -    Operation Exception.

Field starts or ends in the wrong place in the record. AEIZ (resp=26) ITEMERR - Occurs when the item number specified or implied by a READQ TS, or a WRITEQ TS with the rewrite option, is invalid; or if the QUEUE referred This site allows you to ask questions and get answers from various posters, you may also answer any posts if you feel like you have input to give. http://ibmmainframes.com/about2559.html The primary function of the JCT is to register the control information of the system log and journal files AEYH (resp=44) QIDERR - Occurs when the symbolic name identifying the QUEUE

Some new blocks have to allocated and is an admin level job AEIS (resp=19) NOTOPEN - The data set or Vsam is not open. If a TSO session times     out you will probably get an S522 abend code. AEID indicates an End of file condition. TRSW The Transfer Switch received by the ADIN routing program was incorrect Comments Sign in|Recent Site Activity|Report Abuse|Print Page|Powered By Google Sites mainframesguru.inSearch this site JCL ABEND CodesCICS ABEND CodesCICS Interview

  • The amount of unmapped data moved to the user's area is limited to the length specified in the LENGTH option.
  • AEI9 (resp=36) MAPFAIL - Occurs if the data to be mapped has a length of zero or does not contain a set buffer address (SBA) sequence.
  • This indicates either a logical loop or that the system is overloaded, ultimately it will bring the whole CICS down.
  • NATV The ADIN routing program was entered in Native Mode, instead of the normal RETURN mechanism.
  • Votes Salutes Topic Title Votes Salutes EJECT Verb in COBOL 22 Cobol Multiple Choice Questions By Shravan Wipro 18 what is index or subscript in cobol.
  • An uncontrolled loop moved data on top of instructions.

This is sometimes the result of a task being cancelled/forced by Operations. DikDudeModeratorJoined: 22 Jul 2011Posts: 1001Location: usa 1 votes 0 salutes Posted: Fri Oct 14, 2011 12:15 am Post subject: A little bit of looking could have found this: Check that the program is in an appropriate Load Library (i.e., one defined to the current CICS system). please give me brief ex 2 2 static and dynamic calls 2 2 DB2 Certification Guidelines 2 2 Cobol Multiple Choice Questions By Shravan Wipro 2 2 Hexadecimal to decimal conversion

It usually means a problem with the data set. have a peek at these guys o        The length of a record read during an input operation (with the into option) exceeds the value specified in the length option; the record is truncated, and the data area Application should be checked for DISABLED, and display a message to the user, rather than abending. This may be due to a deadlock.

ADP Operations is in charge of canceling transactions. In plain words it means CICS has not identified the terminal the transaction is run on. From the CICS Application Programming Reference manual on the RECEIVE MAP command (emphasis added): MAPFAIL occurs if the data to be mapped has a length of zero or does not contain check over here In order, most likely first: o        In test, the WSCA copybook length does not match the DFHCOMMAREA FILLER.

If the amount of main storage cannot be increased, reduce the number of tasks in the system to avoid short-on-storage situations. If you have an "old-style" program using Handle Condition, there is more to say, and recommendation is to just go away from this styel/model. If this post answer your question.

please give me brief ex 15 jcl sort to add leading zeroes 13 SOC 7 abend - interview question 13 what is static or dynamic call in cobol 13 How to

There are CICS parameters that determine how long a task can run without giving up control. S222    -    Means job was cancelled by a user or operator without a dump. For instance, when exceeding 16 extents of a PDS. U1056   -   Program didn't close a file before ending   DB2 Return Codes    00      -           Successful +100     -           End of cursor / Successful Row not found -104     -          

o        A REWRITE, or a DELETE, was issued but no previous READ with UPDATE command was issued. AEI9 is a MAPFAIL condition, AEIO indicates a duplicate key (DUPKEY) condition. AEIO (resp=15) DUPKEY - Occurs if a record is retrieved via an alternate index in which the key that is used is not unique. this content At ADP, this generally happens on test CICS after a checkin/LI function.

i.e. of 16 extents already allocated) U1026   -   COBOL sort failed. for null values 1 create a table in such a way that Delete cannot be used? 1 Call & Execute a COBOL-DB2 from a COBOL program? 1 UDS2000 utility program 1 On test CICS /native CICS screen after this abend, use DPOC to open the file or manually go the native CICS screen and open the file.

o        An attempt is made to start a browse with a REQID already in use for another browse. Find record description of creating program. Guest Says: How do u handle it...is it using handle abend? Trying to use File Section variables without opening the file      (Missing Select statement (during compile), Bad Subscript / index, Protection Exception,        Missing   parameters on called sub-program, Read / Write

REASON CODE   SQLCODE  -112, Error: THE OPERAND OF A COLUMN FUNCTION IS ANOTHER COLUMN FUNCTION   SQLCODE  -111, Error: A COLUMN FUNCTION DOES NOT INCLUDE A COLUMN NAME   SQLCODE  o        A RETURN command with the Commarea option is issued in a program that is not at the highest logical level. If this post answer your question.